[HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\NETIA\NA-ER 4\Alarms]

<< Click to Display Table of Contents >>

Navigation:  Technical Documentation > NA-ER > Configuration > NA-ER Registry description >

[HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\NETIA\NA-ER 4\Alarms]

This key is used to configure the parameters for the alarms that NA-ER can emit.

In the case where a relay card is present in the machine, an alarm signal can be sent in case of accidental closure of NA-ER.

This feature is only available if the Sentinel is active.

 

[HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\NETIA\NA-ER 4\Alarms]

"Blank duration Sec"="15"

Set the minimum duration of a blank, in seconds, to trigger an alarm.

CPU % threshold = 75


CPU % Update mn = 5


CPU duration sec threshold = 5


"GPI Address"="0x000"

Used to enter the address of the GPI card (0x000 = no card present).

"Level for blank detection dB"="-30"

Set the audio level below which it is considered to be a blanck.

"Levels Status Update Mn"="1"

Interval in minutes between 2 audio level alarms (white or clipping).

"Win Messaging Receiver"=""

Send system notification messages to a machine.

 

Cette clé contient plusieurs sous clés en fonction du type d'alarme :

 

[HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\NETIA\NA-ER 4\Alarms\AutoRestart on Blank]

[HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\NETIA\NA-ER 4\Alarms\Idle Recording]

[HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\NETIA\NA-ER 4\Alarms\Pilot Failure/Detached]

[HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\NETIA\NA-ER 4\Alarms\Playing Blank]

[HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\NETIA\NA-ER 4\Alarms\Playing Empty Zone]

[HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\NETIA\NA-ER 4\Alarms\Playlist Failure]

[HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\NETIA\NA-ER 4\Alarms\Playlist Item Error]

[HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\NETIA\NA-ER 4\Alarms\Playlist Item Skipped]

[HKEY_LOCAL_MACHINE\SOFTWAREWOW6432Node\NETIA\NA-ER 4\Alarms\Playlist Self Stopped]

[HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\NETIA\NA-ER 4\Alarms\Recording Blank]

 

Each subkey contains the following values, allowing you to independently configure the actions to perform for each type of alarm:

 

"Event Log"="Yes"

Sets whether the alarm is logged in the Event Manager.

"GPI Channel N°"="-1"

Sets the GPI output number to be activated during an alarm. Allows you to enter the address of the GPI card

(-1 = no GPI action).

"GPI Channel Normal State"="Off"

Sets the GPI action to Perform, depending on the normal state of the GPI:

Off: The output will be activated during an alarm.

Off: The output will be disabled during an alarm.

Toggle: 50ms pulse

"NDA Messaging"="No"

Defines whether the alarm is to be sent to the NDA Messaging service (as well as the Logger).

"Win Messaging"="No"

Defines whether the alarm is to be sent to the Windows System Notices service.