<< Click to Display Table of Contents >> Navigation: Technical Documentation > NA-ER > Configuration > NA-ER Registry description > [HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\NETIA\NA-ER 4\Alarms] |
This key is used to configure the parameters for the alarms that NA-ER can emit.
In the case where a relay card is present in the machine, an alarm signal can be sent in case of accidental closure of NA-ER.
This feature is only available if the Sentinel is active.
[HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\NETIA\NA-ER 4\Alarms] |
|
"Blank duration Sec"="15" |
Set the minimum duration of a blank, in seconds, to trigger an alarm. |
CPU % threshold = 75 |
|
CPU % Update mn = 5 |
|
CPU duration sec threshold = 5 |
|
"GPI Address"="0x000" |
Used to enter the address of the GPI card (0x000 = no card present). |
"Level for blank detection dB"="-30" |
Set the audio level below which it is considered to be a blanck. |
"Levels Status Update Mn"="1" |
Interval in minutes between 2 audio level alarms (white or clipping). |
"Win Messaging Receiver"="" |
Send system notification messages to a machine. |
Cette clé contient plusieurs sous clés en fonction du type d'alarme :
[HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\NETIA\NA-ER 4\Alarms\AutoRestart on Blank] |
[HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\NETIA\NA-ER 4\Alarms\Idle Recording] |
[HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\NETIA\NA-ER 4\Alarms\Pilot Failure/Detached] |
[HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\NETIA\NA-ER 4\Alarms\Playing Blank] |
[HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\NETIA\NA-ER 4\Alarms\Playing Empty Zone] |
[HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\NETIA\NA-ER 4\Alarms\Playlist Failure] |
[HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\NETIA\NA-ER 4\Alarms\Playlist Item Error] |
[HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\NETIA\NA-ER 4\Alarms\Playlist Item Skipped] |
[HKEY_LOCAL_MACHINE\SOFTWAREWOW6432Node\NETIA\NA-ER 4\Alarms\Playlist Self Stopped] |
[HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\NETIA\NA-ER 4\Alarms\Recording Blank] |
Each subkey contains the following values, allowing you to independently configure the actions to perform for each type of alarm:
"Event Log"="Yes" |
Sets whether the alarm is logged in the Event Manager. |
"GPI Channel N°"="-1" |
Sets the GPI output number to be activated during an alarm. Allows you to enter the address of the GPI card (-1 = no GPI action). |
"GPI Channel Normal State"="Off" |
Sets the GPI action to Perform, depending on the normal state of the GPI: Off: The output will be activated during an alarm. Off: The output will be disabled during an alarm. Toggle: 50ms pulse |
"NDA Messaging"="No" |
Defines whether the alarm is to be sent to the NDA Messaging service (as well as the Logger). |
"Win Messaging"="No" |
Defines whether the alarm is to be sent to the Windows System Notices service. |