This menu allows you to match the logical relay from the database to a relay.
For each 16 relays, it is possible to configure the rest state, the state during action and the duration of the action.
Example : The GPI "0" is placed on a sound in Production.
When reading this sound, the application will detect the GPI and activate the relay regarding the following setting :
•State of the relay before GPI (rest) : OFF
•State at detection of GPI : ON
•Duration on "ON" : 1000 ms.
The action duration is set in millisecondes.
If the duration is "0", the action will be permanent. This mode will allow to go from one state to the other when detecting, and to stay in this state as long as no other GPI is detected.
The initial state can be placed at ON or OFF.
4 different types of actions :
•OFF
•ON
•SWITCH
•DATABASE
If the switch mode is activated, the relay will take the reverse state found. If a duration is indicated, the reverse state will be activated for this duration.
If the choice DATABASE is made, relays will be activated following the setting made in Radio-Assist, Production tab.